Every input that a tool user can enter or select in the EPD Generator of Dawn AI, with its parameter ID, unit, allowed range or menu, the evidence to keep, and whether it is locked on library parts.

Free-variable reference

This page lists the variable input data of the tool: every value that a tool user can enter or select. All other content is fixed in the tool version. The overview lists the fixed content.

Each input has a parameter ID (P-ID). The tool project report and the sensitivity assessment use the same P-IDs. P-01 to P-43 are the IDs of the tool project report v2. P-44 to P-55 are new inputs from the module D, A4/A5 and use stage work. P-56 to P-59 are new inputs from the declared unit work and the EN 17213 technical characteristics. The IDs from P-44 are proposals until the tool project report v3 confirms them.

How to read the table

ColumnMeaning
P-IDThe parameter ID
InputWhat you enter or select, and the UI place
UnitThe unit of the value. "Text" is free text. "Menu" is a pre-defined list.
Range or menuThe values that the tool accepts. The tool refuses a value outside this range when you save.
Evidence to keepThe document that supports the value. The verifier can ask for it.
Locked on library parts"Yes": the value comes from the library part and you cannot change it. "No": you enter it.

A library part is a material, utility, transport service or packaging item from the verified tool version. Your organisation cannot create or edit these parts. Your own standard parts (components) stay editable.

Product and bill of materials

P-IDInputUnitRange or menuEvidence to keepLocked on library parts
P-01Product record: name, SKU, description, image (Info tab)Text, fileName is necessaryProduct data sheetNo
P-02Bill of materials (BoM): parts and sub-products (BOM tab)MenuParts and products of your organisationBoM or production recipe for the data periodNo
P-03Quantity per BoM lineUnit of the partMore than 0BoM, production recordsNo
P-04Production loss per BoM line (Production tab)%0–100 %Scrap or yield records, 12 monthsNo
P-05Product variants: lines left out, added or changedMenu, numberQuantity more than 0, loss 0–100 %, name necessaryBoM of each variantNo
P-06Own part record: name, SKU, description, unitText, menuName necessaryPart specificationNo. You cannot create library parts.
P-07Mass per unit of an own partkg (shown in the weight unit of your organisation)Any number, or empty. The tool has no range check. An empty mass gives no material impact, transport or end of life for the part.Weighing records, drawings, supplier data sheetsNo. Yes on library parts.
P-08Material composition of an own part: material and share by mass%Each share 0–100 %. The part page saves only a total of 100 %. Materials only from the library.Material declarations, drawingsPartly: the materials are library parts
P-56Declared unit of your organisation (Settings › EPD tool). Only when the PCR does not set the declared unit.Menu1 item, 1 m², 1 kg. No selection: 1 item. When the PCR sets the declared unit, the field shows "Set by the PCR" and you cannot change it.Declared unit rule of the PCR or the c-PCRNo
P-57Width and height of the product (Info tab, Dimensions card). The card shows when the declared unit is 1 m². The variants of an assembly use the same values.mMore than 0, or empty. Both values are necessary before "Submit for review" when the declared unit is 1 m². The tool does not set or check a standard size.Product drawing or data sheet with the sizeNo

Suppliers, transport and production sites (A1–A3)

P-IDInputUnitRange or menuEvidence to keepLocked on library parts
P-09Origin of a material in an own part: country or region and share%Each share 0–100 %, total 100 % when set. Does not change the results.Supplier declarationsNo
P-10Supplier record: name, address, countryTextName necessarySupplier listNo
P-11Supplier share per part%0–100 % per supplier. The tool does not check the total. No share entered: equal split.Purchase volumes per supplier, 12 monthsNo. Yes on library parts.
P-12Inbound transport route per supplier: legs, transport mode, distancekm, menuAt least 1 leg. Distance more than 0 km. Mode from the library.Supplier addresses, freight documentsNo. Yes on library parts.
P-13Utilities and energy per unit of product or part (Production tab)Unit of the utilityMore than 0. Utility from the library. One row per utility.Metered consumption, 12 monthsNo. Yes on library parts.
P-14Production site: name, address, country, and the products made there (Locations)Text, menuName necessary, up to 200 charactersSite listNo
P-15Site outputs and annual volumeNumber, volume unitAny number, or empty. A volume of 0 or less takes no share of the site totals.Production statistics per site, 12 monthsNo
P-16Allocation basis for site totalsMenuVolume, weight, priceJustification of the allocation basis, unit prices if price is usedNo
P-17Site utility totals and sub-processesUnit of the utilityMore than 0. Utility from the library.Utility bills and meter readings, 12 monthsNo
P-18Site waste streams: name, amount, treatment route shares, data setsUnit, %Amount more than 0. Route shares 0–100 %, total 100 %. The sealing check does not cover these data sets.Waste collector statements, 12 monthsNo
P-19Location impact rule for products made at several sites (organisation setting)MenuWeighted average, sequentialDescription of the production flow between sitesNo
P-20Transport of production waste and transport to the factory gatekm, menuAs P-12Waste collector and logistics recordsNo
P-21Packaging of the product and of own partsUnit of the packagingMore than 0. Packaging from the library. One row per item.Packaging specificationNo

A4 and A5

P-IDInputUnitRange or menuEvidence to keepLocked on library parts
P-22Transport to the building site (A4): legs, mode, distancekm, menuAs P-12. The transported mass is calculated.Sales and delivery statistics by marketNo
P-23Product lost during installation (A5)%0–100 %Installer data, product standardNo
P-24Installation inputs (A5): energy, water, ancillary materials (Use tab, installation category)Unit of the partMore than 0, per declared unit (not per year). Utility, material or standard part. One row per part.Installation instructionsNo
P-50A4 scenario values on the EPD tab: distance, approach, bulk density, volume capacity utilisation factorkm, %, kg/m³Any finite number, or a value from the menu of the field. A changed value that drives the results gives a warning. The approach becomes "case specific".Source of each changed valuePartly: vehicle type, transport type, fuel type, capacity utilisation, fuel consumption and power consumption come from the data set ("From dataset")
P-51A5 scenario values on the EPD tab: A5 amounts and wasteMJ, m³, kgAny finite number, or a value from the menu of the field. A changed value that drives the results gives a warning. The approach becomes "case specific".Installation instructions, source of each changed valueNo

Use stage (B1–B7)

The use-stage page explains these inputs step by step.

P-IDInputUnitRange or menuEvidence to keepLocked on library parts
P-25Reference service life (RSL): amount and unit (Expected Lifetime card)yearsMore than 0. A time unit makes the amount the RSL. Empty: factor 1. Service life in years up to 9999.99.RSL evidence: see P-45No
P-26Use-stage inputs: utilities and materials, each with a categoryUnit of the partMore than 0. One row per part and category. Releases (B1), maintenance (B2), operational energy (B6), operational water (B7): per year. Repair (B3): total over the RSL. Replacement (B4), refurbishment (B5): per exchange.Product documentation, test reportsYes, for the use inputs of a library part
P-27Exchanged parts (Spare parts card): category, component service life, quantity per exchange, number of exchangesyears, numberCategory: maintenance (B2), repair (B3), replacement (B4), refurbishment (B5). Service life more than 0, up to 9999.99. Quantity per exchange more than 0. Number of exchanges: whole number, 0 or more.Maintenance instructions, component test dataYes, for the spare parts of a library part
P-44Declared modules (EPD tab)Tick boxA4, A5 and B1–B7 can be ticked. A module that shows "Set by the PCR" cannot change: the PCR always declares it or never declares it. A1–A3, C1–C4 and module D are always declared. A ticked module with no inputs is declared as 0. A module that is not ticked is ND and is left out.—No
P-45RSL kind, basis, justification and in-use conditionsMenu, textKind: RSL, ESL. Basis: ISO 15686, PCR or standard default, manufacturer, test, product standard, estimate, field data, warranty. Justification up to 5000 characters. In-use conditions A–G.Evidence for the basis. With the EN 17213 feature: ISO 15686-8 data record for an RSL over 30 yearsNo
P-46Default use-stage scenario (EPD tab). Only for an organisation with the EN 17213 feature.MenuB2 functional check and lubrication: low use 0.5 per year, normal use 1 per year, heavy use 2 per year, other. Cleaning: rarely 1 per year, frequently 4 per year, other. Cleaning method: by hand, by machine. Component service life: insulated glass unit (IGU) at most 30 years, drive or closer 20 years, blind or shutter 25 years.Source of the menu entry (EN 17213:2020+A1:2025, Annex G.2.3 and §6.3.5.4.2)No. The menu values are fixed in the tool version.
P-47Use-stage deviation justificationTextUp to 4000 characters. Necessary for "other", a changed cycle, a changed number of exchanges, a component service life outside the menu, or a part in replacement (B4).Evidence for the deviation (ECO VG 10.3)No
P-48B6–B7 use scenario: frequency of use, period of use, power output, energy efficiency, emissionsper day, h per year, kW, text0 or more. Period of use more than 8760 h per year gives a warning.Product data sheetNo
P-49B1 release statementTextDefault "No emissions in normal use" when B1 is declared as 0. You can change it.Emission test reportsNo

C1–C4 and module D

P-IDInputUnitRange or menuEvidence to keepLocked on library parts
P-28End-of-life scenario per material for this product (End of Life tab)%Each route 0–100 %. The routes without a module D credit total 100 %. The data sets behind the routes are fixed.National or regional waste statisticsNo. The default shares come from the library material.
P-29Deconstruction inputs (C1)Unit of the utilityMore than 0. Utility from the library.Demolition practice dataNo
P-30Transport to waste processing (C2)km, menuAs P-12. The mass is calculated.Regional waste logistics dataNo
P-31Waste processing for the product: data set and amountUnit of the data setAmount more than 0, or empty. The sealing check does not cover this data set.Justification of the processing stepNo
P-41C1–C4 and module D scenario values on the EPD tabText, numberAny text, or any finite number. The tool has no range check. A changed value changes the declaration only, not the results.Scenario sourcesNo
P-52Value-correction factor (Q), with justification and point of substitution0–1, textQ 0–1. Empty: Q counts as 1, "not confirmed". Q other than 1 needs a justification. Used on module D credits from C3 and C4, and from parts exchanged in B2–B5.Market price or quality data of the secondary materialYes, on library materials: the tool owner sets Q and the point of substitution. You can enter Q on your own site waste streams (P-18). On a stream in the production-waste phase, the tool refuses a new Q, because production waste gives no module D credit. On a stream in the end-of-life phase, Q changes module D.
P-53Landfill gas: CH4 share, capture rate, source0–1 (shown in %), text0–1. Empty CH4 share: the IPCC default of 50 % applies. Only on landfill routes.Landfill operator dataYes, on library materials. No, on your own site waste streams (P-18), but there the values do not go into the EPD Hub request.
P-54Route category of a custom end-of-life typeMenuReuse, recycling, energy recovery, incineration, landfill, other, or inferred from the credits—No
P-55Secondary material (SM) overridekg/kg0–1, with a justificationSupplier declaration of recycled contentYes. Only the tool owner can set it. Combine the recycled and the virgin library materials instead.

EPD details, texts and review

P-IDInputUnitRange or menuEvidence to keepLocked on library parts
P-32Products in one EPD (multi-product EPD)MenuUp to 200 other products. Same PCR and tool version. Each product has the width and height, or the mass, that the declared unit needs (P-57). Not in another EPD draft. GWP-fossil A1–A3 at most 50 % above the lowest product.Product range definitionNo
P-33EPD details: site representation, product representation, type of grouping, grouping method, variationMenu, %EPD Hub option lists. Variation 0 or more. A saved answer replaces the calculated answer.Variation calculation from the toolNo
P-34Product name on the EPD, product description, company descriptionTextName up to 255 charactersProduct documentationNo
P-58Thermal transmittance (U-value) (EPD tab, Product). Only for an organisation with the EN 17213 feature.W/m²KOptional. More than 0, up to 10 W/m²K. The tool does not keep a value outside the range.Test report or calculation according to the product standard (EN 14351-1)No
P-59Solar factor (g-value) (EPD tab, Product). Only for an organisation with the EN 17213 feature.NumberOptional. 0–1. The tool does not keep a value outside the range.Test report or calculation according to the product standard (EN 14351-1)No
P-35Place of production, packaging type, production technologyTextPlace of production and packaging type are necessary before "Submit for review"Site and process descriptionNo
P-36Life cycle descriptions (A1–A3, A4–A5, B1–B7, C1–C4, module D, electricity, data quality)TextAI draft, which you can change. Sent only for declared modules.Internal review of the texts against the modelNo
P-37Place of installation and use, origin of raw materialsTextFree textSales statistics by marketNo
P-38REACH and SVHC substance declarationMenu, %, tick boxShare 0 or more, % of the product mass. Both confirmations are necessary before "Submit for review".Supplier REACH declarations, safety data sheetsNo
P-39Data period: end date of the 12-month periodDateEmpty: the default period of your organisationRecords that show all primary data are in the periodNo
P-40Type of verificationMenuThe four EPD Hub verification typesVerification contractNo
P-42Company data: name, address, contact, VAT number, website, logo, markets, product sectorText, menuProduct sector: the four EPD Hub sectorsCompany registration dataNo
P-43Reviewer for the four-eyes reviewMenuA member of your organisation with the EPD reviewer role, who did not create, edit or submit the EPDRecord of the internal reviewNo

Inputs that the tool checks late

The tool accepts some values without a check when you save. Examine these values before "Submit for review":

  • P-07: a missing or wrong mass of an own part.
  • P-11: supplier shares that do not total 100 %.
  • P-57: an empty width or height when the declared unit is 1 m². The tool accepts the empty value, but "Submit for review" is then not available.
  • P-18 and P-31: the data sets of waste streams and waste processing. The sealing check does not cover them.
  • P-41, P-50 and P-51: changed scenario values in the declaration. The tool has no range check on them.

Subscribe to our newsletter