Tutorials/EPD Generator
2. PCR
Which product category rules the EPD Generator applies, where you see them in the tool, and what they fix in your EPD.
2. PCR
Rules that the tool applies
The tool makes EPDs under these rules:
| Rule | Version | What it sets |
|---|---|---|
| EN 15804+A2 | EN 15804:2012+A2:2019/AC:2021 | The core rules: modules, indicators, allocation, cut-off rules, module D |
| EN 17213 | EN 17213:2020+A1:2025, c-PCR for windows and pedestrian doorsets | The default scenarios for the use stage, the service lives of components, and the rules for the reference service life |
| EPD Hub PCR | Core PCR v1.2.1 | The EPD Hub rules for the calculation and the EPD |
| EPD Hub GPI | General Program Instructions v1.3.1 | The programme rules: verification, validity, the EPD Hub request |
Dawn assigns one PCR to your organisation. The PCR is part of the tool version. You cannot select or change the PCR in the tool.
NOTE: The tool applies the edition EN 17213:2020+A1:2025. It applies the EN 17213 rules only if your organisation has the EN 17213 feature. The rules of EN 15804+A2 and the EPD Hub PCR apply to every organisation. See the use-stage page.
Examine your PCR
- Open Settings, and then the EPD tool tab.
- Read the PCR and the tool version under Current library version.
- On the EPD tab of a product, open Method. Examine the standard and the PCR fields. The tool fills them from the tool version.
Dawn can move your organisation to a different PCR. The EPD tool tab then shows "Your PCR is now" with the new tool version. Update to that tool version before you make a new EPD.
What the PCR fixes in your EPD
- Declared unit. 1 item, 1 m² or 1 kg. When the PCR sets the declared unit, Settings › EPD tool shows it as "Set by the PCR" and you cannot change it. When the PCR does not set it, you select it there (P-56). You always model one produced item. The tool converts the results, the masses and the scenario amounts to the declared unit. For 1 m², it uses the width and height that you enter for the product (P-57). For 1 kg, it uses the mass from the bill of materials (BoM). See 3. Product model.
- Declared modules. A1–A3, C1–C4 and module D are always declared (EN 15804+A2, 5.2). You select A4, A5 and B1–B7 on the EPD tab. The PCR can fix one of these modules: always declared or never declared. The tool version keeps this rule, and the EPD tab shows the module as "Set by the PCR".
- Indicators. The core indicators, the "additional environmental impact indicators", the resource use indicators and the output flows of EN 15804+A2. The tool calculates all of them. You cannot remove an indicator.
- Calculation rules. Allocation, cut-off rules, the end-of-waste state and module D follow EN 15804+A2. The methodology describes each rule with its clause.
Next step
Go to 3. Product model.