Dawn
Tutorials/EPD Generator

Entering Use-Stage Inputs (B1–B7)

How to enter the service life, maintenance, repair, replacement, operational energy and water of a product in Dawn, so the EPD declares modules B1–B7 correctly.

Entering use-stage inputs (B1–B7)

This guide shows how to enter what happens to a product while it is in use: its service life, cleaning and maintenance, parts that are exchanged or repaired, and the energy and water it uses. Dawn books each input into one EN 15804 module, B1 to B7, and builds the EPD's use-stage scenarios from the same inputs. The calculation is described in the methodology, section 6.6.3.

You enter everything on the assembly's Use tab, except the declared modules and the default-menu choices, which are on the EPD tab.

Most rules on this page come from EN 15804+A2, ISO 15686-8 and the EPD Hub core PCR, and they apply to every product. Some rules come from EN 17213:2020+A1:2025, the product category rules for windows and doors. Dawn applies those only if your organisation has the EN 17213 feature. Without the feature, you do not see the default menu or the service-life tiers at 30 and 50 years, and Dawn raises none of the EN 17213 issues. This page marks each EN 17213 rule.

1. Set the service life

On the Expected Lifetime card:

  1. Enter the lifetime in years. This is the reference service life (RSL) of the EPD, and every per-year amount is multiplied by it.
  2. Choose whether it is an RSL or an estimated service life (ESL).
  3. Pick its basis: PCR or standard default, manufacturer's declaration, test results, product standard, ISO 15686, field data, estimate, or warranty.
  4. Add a justification when Dawn asks for one, and tick the in-use conditions it applies to.

Dawn asks for a justification for an estimate, a manufacturer's value and a warranty. A warranty is a guarantee period, not a measured service life, so Dawn also warns about it.

If your organisation has the EN 17213 feature (windows and doors), these rules also apply (EN 17213:2020+A1:2025 §6.3.4 and Annex A, and the EPD Hub PCR, Annex I):

  • An RSL needs all of B1–B5 declared.
  • An RSL over 30 years needs a justification. Use the data record of ISO 15686-8 §5.4.4.1 as the template, and add at least one exchange of the insulating glass unit (IGU) when the product has one.
  • An RSL over 50 years also needs evidence that spare parts remain available.

2. Enter exchanged and repaired parts

On the Spare parts card, add each part that is exchanged or repaired during the service life and choose its spare-part category:

CategoryUse it forModule
Maintenance (B2)Planned exchange of worn parts: IGU, seals, hardwareB2
Repair (B3)A broken part replaced after damageB3
Replacement (B4)The whole product replacedB4
Refurbishment (B5)Restoring the whole element to its functionB5

Worn parts belong in Maintenance (B2), and only the whole product belongs in Replacement (B4). This follows EN 15804+A2 §6.3.5.4.2 and applies to every product. EN 17213:2020+A1:2025 §6.3.5.4.2 says the same for windows and doors. If you book a worn part as a replacement, the EPD needs a justification for the deviation.

For a part in B2, B4 or B5, enter:

  • Component service life in years. Enter the service life of the part. If your organisation has the EN 17213 feature, you can use Pick a default service life to take the EN 17213 default for an IGU (at most 30 years), a drive or door closer (20 years) or a blind or shutter (25 years). A manufacturer's own value takes priority over these defaults.
  • Quantity per exchange. How many of the part one exchange uses.

Dawn then shows Exchanges over the RSL, calculated as ⌈RSL ÷ service life⌉ − 1. For example, an IGU with a 25-year service life in a 30-year RSL is exchanged once. The count is a default: you can change it, but a changed count needs the use-stage deviation justification on the EPD tab. Without a component service life, the quantity you enter is used as the total over the RSL, and Dawn asks you to justify it.

For a repair, enter the total quantity over the RSL. If your organisation has the EN 17213 feature, B3 covers accidental damage only, and only when the place of installation is known and the expectation of damage is justified, for example in a school (EN 17213:2020+A1:2025 §6.3.5.4.2).

Each exchanged part books its production, the transport to site and to waste treatment, its end of life and the installation-loss share into the module of its category. A part with no dataset or published LCA of its own gets its production from its material breakdown. If Dawn cannot calculate the production of a part, the exchange books nothing and Dawn shows a blocking issue. Dawn also warns when the mass of the part's materials does not fit its declared weight (more than ×2 or less than ×0.5, or over 100 kg with no weight).

3. Enter cleaning and maintenance inputs

On the Maintenance card, add the energy, water and cleaning agents used for cleaning, inspection and lubrication. They book in B2. Enter them per year. The energy needed to exchange a worn part also goes here, per year: an exchange made once in 30 years is spread over the years.

Energy, water or materials used to carry out a repair, replacement or refurbishment go on the Repair, replacement and refurbishment inputs card:

  • Replacement (B4) and Refurbishment (B5) rows are per exchange event. Enter what one event uses; Dawn multiplies it by all the exchange events of that module.
  • Repair (B3) rows are the total over the service life.

4. Enter operational energy and water

  • Operational energy (B6) card. Energy the product uses in operation, such as the electricity of a door operator, per year. Use the low-voltage electricity market mix of the country of use where you can; Dawn warns about any other mix and names the one used in the EPD. If your organisation has the EN 17213 feature, leave out electric motors and devices for shutters, blinds and for opening or closing. EN 17213:2020+A1:2025 §6.3.5.2 keeps them outside the EPD, and their manufacturer provides a separate EPD. Dawn cannot take B6 from the EPD of a device.
  • Operational water (B7) card. Water the product uses in operation, per year. Water on the operational energy card is flagged so you can move it to B7.
  • Releases (B1) card. Substances released to air, soil or water during use, per year.

Each card shows a badge with the module it books into for your organisation. A card marked Not mapped: books nothing is not booked yet in your tool version; Dawn blocks the EPD until the module is mapped, so B1 is never declared as zero over inputs that were not counted.

5. Declare the modules and choose the default scenario

On the EPD tab:

  1. Under the declared modules, tick the B modules the EPD declares. A module you declare with no inputs is declared as zero.
  2. If your organisation has the EN 17213 feature, pick under Default use-stage scenario the B2 functional check and lubrication frequency (low, normal or heavy use), the Cleaning frequency and the Cleaning method. These are the default scenarios of EN 17213:2020+A1:2025 Annex G.2.3, labelled with their source. Under Service lives of exchanged parts, pick the menu entry and the service-life basis of each exchanged part. The menu appears only with the EN 17213 feature.
  3. Write the use-stage deviation justification if you change the exchange count or book a worn part in B4. This applies to every product. With the EN 17213 menu, it also applies if you choose Other or move away from a default (a different cycle or a different service life). The EPD needs the justification before verification.

The B1, B2–B5 and B6–B7 scenario cards then show every value with its source, ready for the EPD. Check the issues listed under each card before you send the EPD.

Example

A door with a 30-year RSL, a clear infill panel exchanged after 25 years, a hinge repaired once, cleaning and an electric operator. The organisation in this example does not have the EN 17213 feature. With the feature, the operator is a device with its own EPD, and its electricity row is left out.

InputCategoryEnteredOver the RSL
Infill panelMaintenance (B2)service life 25 years, 1 per exchange1 exchange
Cleaning waterMaintenance (B2)12 l per year360 l
Cleaning electricityMaintenance (B2)0.05 kWh per year1.5 kWh (5.4 MJ)
HingeRepair (B3)11
Door operator electricityOperational energy (B6)15 kWh per year450 kWh
Water in operationOperational water (B7)5 l per year150 l

Subscribe to our newsletter